Appendix D Troubleshooting 81
If copyback is enabled—Data is automatically moved back to its original location
once the HBA detects that the failed drive has been replaced. No action is
required.
Failed Disk Drive Not Protected by a Hot-Spare
When an array is not protected by a hot-spare, if a disk drive in that array fails,
remove and replace the failed disk drive. The HBA detects the new disk drive and
begins to rebuild the array.
If the HBA fails to rebuild the array, check that the cables, disk drives, and HBAs are
properly installed and connected. Then, if necessary, use Sun StorageTek RAID
Manager GUI to rebuild the array. For instructions, refer to the Sun StorageTek RAID
Manager Software Users Guide or online Help.
Failure in Multiple Arrays Simultaneously
If there is a disk drive failure in more than one array at the same time (one failure per
array), and the arrays have hot-spares protecting them, the HBA rebuilds the arrays
with these limitations:
A hot-spare must be of equal or greater size than the failed disk drive it’s
replacing.
Failed disk drives are replaced with hot-spares in the order in which they failed.
(The array that includes the disk drive that failed first is rebuilt first, assuming an
appropriate hot-spare is available—see bullet above.)
If there are more disk drive failures than hot-spares, see “Failed Disk Drive Not
Protected by a Hot-Spare” on page 81.
If copyback is enabled, data is moved back to its original location once the HBA
detects that the failed drive has been replaced.
Disk Drive Failure in a RAID 0 Array
Because RAID 0 volumes do not include redundancy, if a disk drive fails in a RAID 0
array, the data can’t be recovered.
Correct the cause of the failure or replace the failed disk drives. Then, restore your
data (if available).