13-22
Adaptec SCSI RAID Software Reference Guide
The Size Keyword
The Size keyword specifies the size of the array. Specify the size as
an integer or a decimal number, followed by the unit keyword MB
(megabytes), GB (gigabytes), or TB (terabytes). A unit keyword is
required with a numeric size value. If no unit keyword is specified,
the ACU exits with an error.
Specify the keyword Maximum to create an array using the
maximum available space, based on the array type and drives
selected. If no Size property is specified, the value Maximum is
used.
Examples:
Size=2.5GB
Size=300MB
Size=Maximum
The StripeSize Keyword
The StripeSize keyword specifies the size of contiguous I/O (in
KB) written to each member of a striped array before switching to
the next member.
This property applies only to array types RAID 0, RAID 5, RAID 50,
and RAID 10. The ACU exits with an error if this property is
specified for any other array types.
The possible values for StripeSize are 16, 32, and 64. Do not
specify a unit keyword for the stripe size because all values are in
kilobytes.
If no StripeSize property is specified and the array type supports
this property, the value 64 is used by default.
Example:
StripeSize=64
The Wait Keyword
The Wait keyword indicates whether the ACU should wait for the
new array’s build/verify or clear to complete before continuing.
The Wait property is optional; if not specified, the ACU waits for
the array’s build/verify or clear to complete before continuing.
Specify Wait=No to allow the ACU to continue while the build/
verify or clear completes in the background.