11-31
enclosure Commands
As the example shows, the power supply status display contains the
following columns:
■ Enclosure
■ Power
■ State
■ Status
The following sections describe the information that the enclosure
show power command can display in these columns.
The Enclosure and Power Columns
The Enclosure column displays the ID associated with the enclosure
management device that you specified on the command line. If you
did not specify an ID, the enclosure show power command
displays the IDs for all enclosure management devices connected to
the controller. In the example, 0 is specified.
The Power column displays the unit number associated with the
power supply that you specified on the command line. If you did
not specify a unit number, enclosure show power command
displays the unit numbers for all power supplies on the enclosure
management device or devices. In the example, there is one power
supply (unit 0) each on enclosure management devices 0 and 1.
The State and Status Columns
The State column displays the state and the Status column displays
the status of the power supply. Specifically, the column can display
the items listed in Table 11-5.
Table 11-5. Power Supply State and Status Values
Status State Meaning
ON OK
The power supply is on and
operational. In the example, power
supply 0 on enclosure management
device 0 has these values.
OFF OK
The power supply is off and
operational. In the example, power
supply 0 on enclosure management
device 1 has these values.
Komentáře k této Příručce