Adaptec 2120S - SCSI RAID Controller Uživatelská příručka Strana 217

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 354
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 216
7-17
disk Commands
disk show defects
To show the number of defects and/or the defect list for a specific
SCSI disk drive, use the disk show defects command.
Syntax
disk show defects [/full{=boolean}]{scsi_device}
Parameters
{scsi_device}
Specifies the ID for the SCSI device for which you want to
display defect information. A SCSI device consists of a SCSI
channel number (for example, 0, 1, 2, 3, etc.), SCSI device ID (0
through 15 inclusive), and SCSI device logical unit number (0
through 7 inclusive). See the scsi_device section on
page 3-7 for more information on how to specify the SCSI
device.
Switches
/full{=boolean}
Specifies whether to display the defect count and the list of
disk defects. If you set this switch to TRUE, the command
displays the list of defects and the number of defects.
This switch defaults to FALSE, which means the command
displays only the number of defects.
Examples
The following example lists the number of defects and the list of
defects for a SCSI disk device (SCSI channel number 1, SCSI device
ID 0, and SCSI logical unit number 0):
AAC0> disk show defects /full=TRUE (1,0,0)
Number of PRIMARY defects on drive: 2
Defect 1 at cylinder 12, head 5, sector 59
Defect 2 at cylinder 550, head 1, sector 44
Number of GROWN defects on drive: 0