Adaptec 2110S - SCSI RAID Controller Instalační příručka

Procházejte online nebo si stáhněte Instalační příručka pro Základní desky Adaptec 2110S - SCSI RAID Controller. Adaptec 2110S - SCSI RAID Controller Installation guide [en] Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 106
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
R
Adaptec RAID
Installation Guide
COMBINED RAID IG.BOOK Page i Monday, September 17, 2001 4:30 PM
Zobrazit stránku 0
1 2 3 4 5 6 ... 105 106

Shrnutí obsahu

Strany 1 - Adaptec RAID

RAdaptec RAIDInstallation GuideCOMBINED RAID IG.BOOK Page i Monday, September 17, 2001 4:30 PM

Strany 2 - Disclaimer

1-2Adaptec RAID Installation GuideSystem RequirementsThe following system requirements are discussed: Storage requirements for drivers and software

Strany 3 - Adaptec, Inc

C-4Adaptec RAID Installation GuideThe Adaptec controller BIOS reports a drive as a disk instead of a drive.This condition can occur if SMOR is used t

Strany 4 - Canadian Compliance Statement

D-1DController Reset ProceduresIn this AppendixThis Appendix describes procedures that you can use to reset your controller in the event the controlle

Strany 5 - Contents

D-2Adaptec RAID Installation GuideNVRAM ResetAdaptec RAID controllers retain their setup parameters even when powered off. These parameters are stored

Strany 6 - 3 Installing the Driver

D-3Controller Reset Procedures2 Insert the Adaptec RAID Installation CD into your drive and restart your system.3 Follow instructions and respond to p

Strany 7

E-1ESpecificationsDC Power RequirementsCurrent RequirementsVoltage (all DC)2000S/2005S3.3 V ± .3 V2110S5 V ± .5 V2400A/3200S/3210S/3400S/3410S 5 V ± .

Strany 8 - E Specifications

E-2Adaptec RAID Installation GuideEnvironmental SpecificationsNote: Forced airflow is recommended, but not required.Ambient temperature without batter

Strany 9

RAdaptec, Inc.691 South Milpitas BoulevardMilpitas, CA 95035© 2000, 2001 Adaptec, Inc.All rights reserved. Adaptec, and the Adaptec logo are trademark

Strany 10 - System Requirements

1-3IntroductionKit ContentsYour Adaptec controller kit includes the following: Adaptec controller and cables, one of the following: Adaptec ATA RAID

Strany 11 - Kit Contents

1-4Adaptec RAID Installation Guide Intelligent hot spares that automatically replace failed drives. When multiple hot spares are available on a contr

Strany 12

1-5IntroductionRAID features, including those for the 2400A, are summarized in the following table:2400A2000S/2005S 2100S 2110S3200S/3400S11The Adapte

Strany 13

1-6Adaptec RAID Installation GuideAbout the DocumentationThe complete documentation set for Adaptec RAID controllers consists of the following: Adapt

Strany 14 - About the Documentation

1-7Introduction Launch RAID configuration utility—Starts Storage Manager, which enables you to configure your RAID and build disk arrays. View docum

Strany 15 - Introduction

1-8Adaptec RAID Installation GuideFiles and FoldersIf your installation process requires you to directly access files on the Adaptec RAID Installation

Strany 16 - Product Documentation on CD

1-9IntroductionErrata and Release NotesBefore beginning your installation, review the errata and release notes associated with the Adaptec controller,

Strany 17 - Errata and Release Notes

1-10Adaptec RAID Installation GuideOverview of the Installation ProcessThe following steps provide an overview of the process of installing and settin

Strany 18

1-11IntroductionCache Memory ModuleAdaptec cache memory modules provide up to 256 MB of high-speed SDRAM disk cache with ECC (Error Correction Coding)

Strany 19 - Cache Memory Module

iiCopyright© 2001 Adaptec, Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in an

Strany 20

1-12Adaptec RAID Installation GuideStorage Management Software OverviewYour Adaptec RAID controller includes the following software tools to manage yo

Strany 21

1-13IntroductionManager Pro. Use Storage Manager if you require these additional operating systems, or if you require a feature that has not yet been

Strany 22 - Safety Information

1-14Adaptec RAID Installation GuideSafety InformationAny device that uses electricity must be treated with caution. To ensure general safety, follow t

Strany 23

1-15IntroductionTo prevent ESD damage, follow these guidelines: Always use an ESD wrist or ankle strap and ensure that it makes skin contact. Connec

Strany 24 - Installing Your Controller

2-12Installing Your ControllerIn this ChapterConfiguring ATA DrivesWhen configuring drives for the Adaptec 2400A, you need to: Select and configure c

Strany 25 - Configuring SCSI Devices

2-2Adaptec RAID Installation GuideATA CablesATA RAID controllers use ATA/100 cables. The cables supplied with your controller kit have a blue connecto

Strany 26 - SCSI Device IDs

2-3Installing Your ControllerLVD and SE DevicesAttaching a single-ended (SE) SCSI device to an LVD bus causes the bus to slow down to Ultra SCSI speed

Strany 27 - SCSI Termination

2-4Adaptec RAID Installation GuideSCSI TerminationThe basics of termination are as follows: Enable termination on the devices on each physical end of

Strany 28

2-5Installing Your ControllerThe following figure shows various SCSI cabling examples. Terminate your SCSI devices as shown in the examples, ensuring

Strany 29

2-6Adaptec RAID Installation GuideInstalling Additional Cache MemoryMany Adaptec RAID controllers can be upgraded with additional cache memory. See Ca

Strany 30 - Adaptec 3200S/3400S Only

iiiRegulatory Compliance StatementsFederal Communications Commission Radio Frequency Interference StatementWARNING: Changes or modifications to this u

Strany 31

2-7Installing Your ControllerSeating the Module – Adaptec 3200S/3400S OnlyHolding the circuit board and module by the edges, slide the module into the

Strany 32 - Installing the Controller

2-8Adaptec RAID Installation GuideSeating the Module – Adaptec 2400A/2100S/3210S/3410S OnlyHolding the circuit board and module by the edges, slide th

Strany 33

2-9Installing Your ControllerFinishing up – All ModelsTo confirm that the modules are properly installed1 Insert the RAID adapter into the system.2 St

Strany 34 - Using SMOR

2-10Adaptec RAID Installation GuideZero Channel RAID Controllers (2000S, 2005S)The Adaptec RAID controllers 2000S and 2005S have unique installation r

Strany 35

2-11Installing Your Controllerare found automatically detect the presence of the first controller and disable their BIOS. The disk controller that has

Strany 36 - Installing the Driver

2-12Adaptec RAID Installation GuideTo run SMOR and configure a new system1 Press Ctrl+A when the Adaptec I2O BIOS message appears during system startu

Strany 37 - Windows 2000

3-13Installing the DriverIn this ChapterThis chapter presents several scenarios for installing the controller driver. Identify the appropriate scenari

Strany 38

3-2Adaptec RAID Installation GuideWindows 2000The following sections describe procedures for installing the Adaptec RAID controller with Windows® 2000

Strany 39

3-3Installing the Driverc Follow instructions and respond to prompts as necessary to get to the Adaptec splash screen.d When you see the Adaptec splas

Strany 40

3-4Adaptec RAID Installation GuideAdding the Controller to an Existing SystemIn this scenario, you are adding an Adaptec RAID controller to a system t

Strany 41 - Windows NT 4.0

ivCanadian Compliance StatementThis Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment Regulations.Cet ap

Strany 42 - Controller

3-5Installing the DriverUpgrading Windows NT to Windows 2000In this scenario, you already have an Adaptec RAID controller installed in your system. Ho

Strany 43

3-6Adaptec RAID Installation Guide7 When the system is restarting, a blue screen appears after the hardware detection message. When prompted to instal

Strany 44

3-7Installing the DriverInstalling the Driver in a New System with Only One ControllerIn this scenario, you are installing an Adaptec RAID controller

Strany 45

3-8Adaptec RAID Installation Guide8 Select Other, then insert the driver disk you created in Step 3.9 Select Adaptec I2O RAID Host Adapter Driver for

Strany 46 - 8 Start up the system

3-9Installing the Driver7 You are prompted to either press S to specify additional controllers or press Enter to continue Windows NT installation with

Strany 47 - Creating the Driver Disk

3-10Adaptec RAID Installation Guide3 Restart the system and open the Control Panel. Click the SCSI Adapters icon. Then select the Drivers tab and clic

Strany 48 - C drive

3-11Installing the Driver4 Insert the driver disk you created in Step 1 and then click Have Disk.5 Select Adaptec I2O RAID Host Adapter Driver for NT

Strany 49

3-12Adaptec RAID Installation GuideCreating the Driver DiskEach of the procedures for installing the driver in each case requires a slightly different

Strany 50 - (OEM SR2 – Version 95B)

3-13Installing the DriverInstalling the Driver in a New Windows 98/Me SystemIn this scenario, you doing a full installation on one disk drive or array

Strany 51

3-14Adaptec RAID Installation Guide11 During one of the device detection start processes, Windows identifies a PCI Card device. Click Next and display

Strany 52

vContents1 Introduction Read this First 1-1System Requirements 1-2Storage Requirements for Drivers and Software 1-2Motherboard Compatibility 1-2Kit Co

Strany 53

3-15Installing the DriverInstalling the Driver in a New System with Windows 95 (OEM SR2 – Version 95B)In this scenario, you are installing a bootable

Strany 54 - Novell NetWare

3-16Adaptec RAID Installation Guide14 Open the Device Manager. Look for a PCI Card entry under the Other Devices category. There may be multiple entri

Strany 55 - NetWare 4.11 Server

3-17Installing the Driver22 If you system contains multiple Adaptec RAID controllers, repeat Steps 14 through 21 for each controller. The system shoul

Strany 56

3-18Adaptec RAID Installation GuideNote: If you are not prompted for a PCI card or memory controller driver, open the Device Manager. If the Device Ma

Strany 57 - NetWare 4.2 Server

3-19Installing the DriverUpgrading Windows 95 to Windows 98/Me (Upgrade Version)If you are upgrading the system from Windows 95 to Windows 98/Me in an

Strany 58 - C drive named nwupdate

3-20Adaptec RAID Installation GuideInstalling the Driver for a Boot Controller in a New NetWare 4.11 ServerIn this scenario, you are installing an Ada

Strany 59

3-21Installing the Driver8 Insert the driver disk you created in Step 1 and run dpt411.bat. This utility copies the necessary files to the C drive.9 R

Strany 60 - NetWare 5 Server

3-22Adaptec RAID Installation Guide3 Shutdown the server. 4 Install and configure your Adaptec RAID controller as a secondary controller according to

Strany 61

3-23Installing the Driverc Remove the Adaptec RAID Installation CD and the driver floppy disk.2 Install and configure your Adaptec RAID controller as

Strany 62 - SCO UNIX

3-24Adaptec RAID Installation GuideInstalling the Driver in an Existing NetWare 4.2 Server In this scenario, you are integrating an Adaptec RAID contr

Strany 63

viAdaptec RAID Installation GuideSeating the Module – Adaptec 3200S/3400S Only 2-7Seating the Module – Adaptec 2400A/2100S/3210S/3410S Only 2-8Install

Strany 64

3-25Installing the Driver13 Select Edit startup.ncf. If needed, edit the file so that i2opci.nlm is listed before bkstrosm.ham in your startup.ncf fil

Strany 65

3-26Adaptec RAID Installation Guide12 Select Edit startup.ncf. 13 Install the latest support pack for NetWare 5.Installing the Driver in an Existing N

Strany 66

3-27Installing the DriverSCO UNIXThe Adaptec RAID Installation CD contains a driver for each version of SCO. You use the CD to create driver disks. Tw

Strany 67

3-28Adaptec RAID Installation Guide3 When prompted for the SCO BTLD disk, insert the driver disk you created earlier (refer to page 3-27).4 Insert the

Strany 68

3-29Installing the DriverAdding the Controller to an Existing UnixWare 7 SystemIn this scenario, you are adding an Adaptec RAID controller to an exist

Strany 69 - Management Software

3-30Adaptec RAID Installation Guide9 To add a drive to a secondary controller, type diskadd cCCbBBtTTdDDFor example, a new drive or array is connected

Strany 70

3-31Installing the DriverLinuxThe Adaptec RAID controller supports Red Hat 7.0 and 7.1 and SuSE 7.0 and 7.1 with kernel versions 2.2.14-5.0, 2.2.16-22

Strany 71 - Installation Prerequisites

3-32Adaptec RAID Installation Guidee Insert a floppy disk and click OK. The system creates the driver disk.f Remove the Adaptec RAID Installation CD a

Strany 72 - NetWare 4.11 and 4.2

3-33Installing the Driver12 Continue with the Linux installation according to the Red Hat documentation.Installing the Driver in an Existing Linux Sys

Strany 73

4-14Installing Storage Management SoftwareIn this ChapterAs described in Storage Management Software Overview on page 1-12, you can use either Storage

Strany 74 - NetWare 5.x

viiContentsInstalling the Driver for a Boot Controller in a New NetWare 4.2 Server 3-22Installing the Driver in an Existing NetWare 4.2 Server 3-24Ins

Strany 75 - Red Hat Linux and FreeBSD

4-2Adaptec RAID Installation GuideSystem RequirementsYou need a system that meets the following minimum hardware requirements: Pentium or equivalent

Strany 76 - Installing Storage Manager

4-3Installing Storage Management SoftwareStorage Manager Pro’s remote management capabilities are only available on your system if it contains a netwo

Strany 77

4-4Adaptec RAID Installation GuideTo install Storage Manager Pro on Windows1 If you are using a Windows 2000 or Windows NT system, verify that you hav

Strany 78 - SCO UnixWare 7

4-5Installing Storage Management SoftwareNote: Storage Manager Pro does not run on JRE 1.2.2. Therefore, if you have JRE 1.2.2 installed on your serve

Strany 79 - ■ K Desktop Environment (KDE)

4-6Adaptec RAID Installation GuideThe autoexec.ncf file now containssearch add SYS:\Adaptec\SMProasmpsrvr.ncf8 Press Esc to exit when prompted.9 To be

Strany 80 - Card and Module Diagrams

4-7Installing Storage Management Software4 From the Select Product Option window, select Adaptec Storage Manager Pro and press Enter. When the process

Strany 81 - Adaptec ATA RAID 2400A

4-8Adaptec RAID Installation GuideInstalling Storage ManagerStorage manager occupies approximately 5 MB of hard disk space.Operating System Compatibil

Strany 82 - Adaptec SCSI RAID 2000S

4-9Installing Storage Management SoftwareConfiguring the Controller Cache in Windows NT and Windows 2000If you are using Windows NT 4.0, Windows 2000,

Strany 83 - Adaptec SCSI RAID 2005S

4-10Adaptec RAID Installation GuideSCO UNIXNote: The Motif version of Storage Manager for SCO UNIX will not display colors correctly if your video dis

Strany 84 - Adaptec SCSI RAID 2100S

4-11Installing Storage Management SoftwareLinuxStorage Manager for Linux requires X-Window support. Storage Manager includes LessTif components and su

Strany 85 - Adaptec SCSI RAID 2110S

viiiAdaptec RAID Installation GuideA Card and Module Diagrams Adaptec ATA RAID 2400A A-2Adaptec SCSI RAID 2000S A-3Adaptec SCSI RAID 2005S A-4Adaptec

Strany 86 - Adaptec SCSI RAID 3200S

A-1ACard and Module DiagramsIn this Appendix➤ Adaptec ATA RAID 2400A A-2➤ Adaptec SCSI RAID 2000S A-3➤ Adaptec SCSI RAID 2005S A-4➤ Adaptec SCSI RAID

Strany 87 - Adaptec SCSI RAID 3400S

A-2Adaptec RAID Installation GuideAdaptec ATA RAID 2400APart DescriptionECCEN ECC enabled LED (green)ECCERR ECC error LED (red)IRQ, 8..1 Adapter activ

Strany 88 - Adaptec SCSI RAID 3210S/3410S

A-3Card and Module DiagramsAdaptec SCSI RAID 2000SPart DescriptionJ6 Flash Mode 0P1 PCI connectorJ6P1AIC7930WCOMBINED RAID IG.BOOK Page 3 Tuesday, S

Strany 89

A-4Adaptec RAID Installation GuideAdaptec SCSI RAID 2005SPart DescriptionJ6 Flash Mode 0P1 PCI connector2005SJ6P1AIC7930WCOMBINED RAID IG.BOOK Page 4

Strany 90

A-5Card and Module DiagramsAdaptec SCSI RAID 2100S Part DescriptionIRQ, 8..1 Adapter activity LEDsJ1 Cache memory socket. (During operation, this soc

Strany 91

A-6Adaptec RAID Installation GuideAdaptec SCSI RAID 2110SPart DescriptionJ5 Pins 1–2 NVRAM resetPins 3–4 Reserved—do not useJ6 Flash Mode 0J10 Interna

Strany 92 - Controller LEDs

A-7Card and Module DiagramsAdaptec SCSI RAID 3200SPart DescriptionECCEN ECC enabled LED (green)ECCERR ECC error LED (red)IRQ, 8..1 Adapter activity LE

Strany 93 - LEDs During Controller Active

A-8Adaptec RAID Installation GuideAdaptec SCSI RAID 3400SPart DescriptionECCEN ECC enabled LED (green)ECCERR ECC error LED (red)IRQ, 8..1 Adapter acti

Strany 94 - Cache Status LEDs

A-9Card and Module DiagramsAdaptec SCSI RAID 3210S/3410SFront ViewBack View — LEDs OnlyAdaptecAIC-7899WHPT370AdaptecAIC-7899WJ14Busy LEDNVRAMJ12J19J1J

Strany 95 - SCSI Bus Status LEDs

A-10Adaptec RAID Installation GuidePart DescriptionECCERR ECC Error LED (red)IRQ, 8..1 Adapter activity LEDsJ1 Cache memory socket. (During operation,

Strany 96

1-11IntroductionIn this ChapterRead this FirstBefore you begin installing your new Adaptec RAID controller, read this chapter. This chapter is an impo

Strany 97 - Troubleshooting

A-11Card and Module DiagramsAdaptec Battery Backup Module - ABM-100This battery is meant to be used only with the 3200S and 3400S, not with the 3210S

Strany 98

A-12Adaptec RAID Installation GuideAdaptec Battery Backup Module - ABM-200This battery is meant to be used only with the 3210S and 3410S, not with the

Strany 99

B-1BController LEDsIn this ChapterAdaptec RAID controllers provide LEDs that let you visually monitor controller activity. Several different controlle

Strany 100

B-2Adaptec RAID Installation GuideLED During Power-upDuring its power-up sequence, the controller passes through the following states in sequence, as

Strany 101 - Controller Reset Procedures

B-3Controller LEDsWhen the power-up sequence is complete, viewing the LEDs can help you determine the operating status of the controller. These LED pa

Strany 102 - Flash Mode 0

B-4Adaptec RAID Installation Guide ECCERR (ECC Error)—Lit (red) when a correctable or noncorrectable error has been detected in a cache memory module

Strany 103

B-5Controller LEDsSCSI Bus Status LEDs – Adaptec 3410S OnlyThe following bus status LEDs are provided: TPOWER_A, TPOWER_B, TPOWER_C, TPOWER_D—Lit when

Strany 104 - Specifications

C-1CTroubleshootingThis appendix provides answers to many frequently asked questions. If a situation occurs that is not covered in this appendix, or i

Strany 105

C-2Adaptec RAID Installation GuideThe controller fails to respond and the IRQ LED (and possibly other LEDs) remains lit.The IRQ LED indicates that the

Strany 106 - RINTED IN SINGAPORE

C-3TroubleshootingThe controller fails to respond and various IRQ LEDs in the 1–4 range flash once per second.This LED pattern indicates an internal m

Komentáře k této Příručce

Žádné komentáře