Command Line Interface
Parameters
{container}
ID number of the array whose assigned failover
disk is to be removed.
{device_ID}
ID for the device to remove as a failover disks.
container remove global_failover {device_ID}
[{device_ID}...]
Removes a global failover assignment.
Parameters
{device_ID}
ID for the device to remove as a failover disk.
container restore RAID5 {container}
Tries to restore a RAID 5 that has a number of dead partitions as
members.
Parameters
{container}
ID number of the RAID 5 to restore.
container scrub [/io_delay={integer}]
[/no_repair={
boolean
}] [/wait={
boolean
}] {container}
Checks and repairs the consistency of a redundant array.
Parameters
{container}
ID number of the redundant array to build.
Switches
/io_delay
Number of milliseconds the controller waits
between I/Os when building the array.
/no_repair
Specifies whether the build operation be
performed without repairing the error.
/wait
If FAL SE (the default), the operation is performed in the
background and the command prompt is returned immediately.
If TRUE, the operation is performed immediately and the
command prompt is returned only when done.