([DPSOH6HVVLRQIRU$SSOLFDWLRQ
We assume that there is a RAID 1 Array Drive which is no longer fault tolerant. Its state is
-1/v, one drive has failed and is therefore no longer accessible on the I/O channel.
The ICP Controller started beeping. The audible alarm can be disabled within GDTMON by
pressing <F2> as soon as the View/Change Settings menu is loaded:
After selecting the Array Drive, we choose the Replace Mirror Drive option.
Before the new drive can be added, the missing drive has to be deleted in the RAID 1 con-
figuration.